  • 3M™ Interam™ Endothermic Mat E-5A-4, 24-1/2 in x 20 ft. (62.23 cm x 6.1 m) roll
  • 3M™ Interam™ Endothermic Mat E-5A-4, 24-1/2 in x 20 ft. (62.23 cm x 6.1 m) roll

    3M ID 7000031969
    • Fast and easy installation
    • Non-flame supporting
    • Low smoke evolution
    • Endothermic materials contain chemically bound water
     More...
    Specifications
    Brand
    Interam™
    Color Family
    Grey
    Fire Rating
    4 Hour
    NPVI Mktg
    Yes
    Org_Code
    AD
    Overall Length (Imperial)
    20 ft
    Overall Length (Metric)
    6.1 Meter
    Overall Width (Imperial)
    24.5 Inch
    Overall Width (Metric)
    622 mm
    Product Colour
    Silver
    Product Series
    E-5A-4
    Product Type
    Endothermic Mat
    Size_LW_Imperial
    20 ft x 24.5 Inch
    Size_LW_Metric
    6.1 Meter x 622 mm
    Trademark 1 (without suffix)
    3M
    Water-tight
    No
    Details
    • Fast and easy installation
    • Non-flame supporting
    • Low smoke evolution
    • Endothermic materials contain chemically bound water
    • Flexible for wrapping around corners and obstacles
    • Aluminum backing

    The 3M™ Interam™ Endothermic Mat E-5A-4 is composed of a combination of materials, including ceramic fibres and inorganic endothermic material. In the event of fire, they help prevent heat penetration via a chemical reaction that absorbs heat energy.

    The 3M™ Interam™ Endothermic Mat is non-flame supporting and offers low smoke evolution, making it an excellent fire barrier for structural steel and electrical circuitry. This mat is composed of a combination of organic and inorganic materials, and includes an aluminium backing. These advanced endothermic materials contain chemically bound water, helping to prevent heat penetration via a chemical reaction which absorbs heat energy. The endothermic mat blocks heat penetration by chemically absorbing heat energy to protect structural steel, cable trays and circuits in conduits. It can provide up to 4 hours of protection for structural steel and up to 3 hours of electrical circuit protection. The Interam endothermic mat meets the following ASTM (UL) and NBN/ISO Standard Test Requirements: ASTM E 84 (UL 723) Surface Burning Characteristics of Building Materials, ASTM E 119 (UL 263) Fire Tests of Building Construction and Materials, ASTM E 1529 (UL 1709) Determining Effects of Large Hydrocarbon Pool Fires on Structural Members and Assemblies, ASTM E 1725 Fire Tests of Fire-Resistive Barrier Systems for Electrical System Components and NBN 713-20/ISO TC 92 Simulated Jet-Fire Test.

    Suggested Applications

    • Designed to help protect critical electrical and structural components from fire