1. 3M Canada

3M™ Rejacketing Sleeve, RJS-3-10FT, 10 ft (3 m) coil, 3.3-25 kV

3M ID 7000006146
  • Installs quickly and accommodates a wide range of cable sizes
  • No torches, heat or special tools required
  • Seals tight and retains resiliency and pressure
  • Excellent resistance to ozone and ultra-violet radiation
 More...
Specifications
Agency Approvals
IEEE
Brand
3M™
Breakout Boot
No
Color Family
Grey
Conductor Size by Voltage
(10 kV, IEC) 70–150 mm², (15 kV, AEIC) 1/0–4/0 AWG, (20 kV, IEC) 25–70 mm², (25 kV, AEIC) 2–1/0 AWG, (3.3 kV, IEC) 120–185 mm², (3.3 kV, JIS) 100–150 mm², (5.0 kV, AEIC) 4/0 AWG–400 kcmil, (6.6 kV, IEC) 60–100 mm², (6.6 kV, JIS) 95–150 mm², (8.0 kV, AEIC) 3/0 AWG–350 kcmil
Dielectric Strength (V/mil)
428 V/mil
Elongation
910 Percent
Inner Diameter After Shrink (Imperial)
0.8 Inch
Inner Diameter After Shrink (Metric)
20.3 mm
Inner Diameter Before Shrink (Imperial)
1.02 Inch
Inner Diameter Before Shrink (Metric)
25.9 mm
Insulation Rejacketing
Yes
Manufacturing Origin
USA
Metallic Shield Diameter Range
0.80 - 1.02 in
Operating Temperature (Celsius)
105
Operating Temperature (Fahrenheit)
221 Degree Fahrenheit
Org_Code
HA
Overall Length (Imperial)
10 ft
Overall Length (Metric)
3048 mm
Product Colour
Dark Grey
Product Type
Splice Jacketing and Rejacketing Kits
Temperature Rating
356°F (180°C) Class H
Tensile Strength (Imperial)
1058 Pound-Force Per Square Inch
Units per Case
1
Voltage Range
3.3 - 25 kV
Details
  • Installs quickly and accommodates a wide range of cable sizes
  • No torches, heat or special tools required
  • Seals tight and retains resiliency and pressure
  • Excellent resistance to ozone and ultra-violet radiation
  • Easy to adjust sleeve length
  • Good solvent resistance
  • Packaged as a 10-foot (3 m) coil
  • Designed to be used in conjunction with 3M™ Cold Shrink Breakout Boots and 3M™ Silicone Rubber Terminations

3M™ Rejacketing Sleeves RJS Series are designed so that 3M™ Cold Shrink QT-III and Q-TIII Silicone Rubber Terminations can be used on 3/C (three conductor) medium voltage shielded power cables of tape shield, wire shield, armoured and non-armoured configurations. Rejacketing sleeves are designed to protect the phase legs (core) of 3/C shielded power cable from exposure to moisture, corrosion, ozone, ultra-violet radiation, physical contact and other hazards that are associated with termination operating environments. The 3M™ Rejacketing Sleeve RJS-5/10 is to be used in conjunction with 3M™ Cold Shrink Breakout Boots and Silicone Rubber Terminations. 3M™ Rejacketing Sleeve RJS-3 has a metallic shield diameter range of 1.28-1.62 inch (32.5-41.1 mm), a voltage range of 3.3-25 kV, and one 10-foot (3 m) coil per case.

Suggested Applications

  • Protect shielded phase legs (cores) of 3/C medium voltage (35 kV and less) power cables after the jacket has been removed in preparation for terminating
Contact a Representative

All fields are required.

  • Enter your 10-digit phone number. Numbers only (5555555555).

3M will use the information to respond to your request and in accordance with our Privacy Policy.



3M takes your privacy seriously. 3M and its authorized third parties will use the information you provided in accordance with our Privacy Policy to send you communications, which may include promotions, product information and service offers.


Loading wheel

Thank you for contacting us! Logo
Thank you!

Your request has been submitted successfully. A representative will contact you shortly.

Sorry Logo

Sorry!

We can’t seem to complete your request. Please try again.

Other 3M Sites:
Partner portal
Follow Us
The brands listed above are trademarks of 3M. Used under license in Canada.
Change Location
Canada - English | Français