  6. 3M™ Cold Shrink Quick Splice Low Voltage, QSLV-M-8-2/0, non-shielded, 1 kV, cable O.D. 0.20-0.75 in

3M™ Cold Shrink Quick Splice Low Voltage, QSLV-M-8-2/0, non-shielded, 1 kV, cable O.D. 0.20-0.75 in

  • 3M ID 7000058804
  • UPC 00051128572368

Quick and easy installation

Seals tight, retains resiliency and pressure

Resistant to acids, alkalies, fungus and UV light

View more details

Details

Highlights
  • Quick and easy installation
  • Seals tight, retains resiliency and pressure
  • Resistant to acids, alkalies, fungus and UV light
  • No special tools or heat source required
  • Accommodates a very wide range of cable sizes
  • Rated for up to 1 kV applications
  • Splices both aluminum and copper conductors
  • Simple installation which requires no tools
  • Offers excellent wet electrical properties and resists water, acids and alkalis
  • Withstands temperatures of -40°C to 90°C (-40 °F to 194°F)
  • RoHS 2011/65/EU Compliant and ANSI Certified
  • Environmental sealing for communication and other non-electrical applications

3M™ Cold Shrink Quick Splice Low Voltage QSLV-M provides quick, reliable insulation and protection for secondary low-voltage splices. Mastic rings at each end provide remarkably wide wire range. Fits 8 AWG to 2/0 AWG.

3M™ Cold Shrink Low Voltage QSLV-M provides quick, reliable insulation and protection for secondary low-voltage splices. The 8-2/0 tube fits 8 AWG to 2/0 AWG and is designed as primary electrical insulation for solid dielectric insulated wire and cable splices rated to 1000 volts. Mastic rings at each end provide remarkably wide wire range. In fact, the two QSLV-M tubes together offer three times the wire range on traditional cold applied products. After installation, a solid internal core remains inside to protect against impact damage. Installation is easy with no torch or tools required. It provides reliable sealing and long-term durability. The tubes are designed to resist fungus, acids and alkalis, and have passed testing for ANSI C119.1. It can be used for direct bury or submersible applications on either aluminum or copper splices.

Suggested applications
  • Primary electrical insulation for 8 AWG–500 kcmil solid dielectric (rubber and plastic) insulated wire and cable splicing rated to 1000 volts, direct bury or submersible
  • Insulation of secondary splices, copper or aluminum conductors
  • Direct bury or submersible applications

Typical Properties

Similar products

Brands 3M
Cable Outside Diameter (Metric) 19 mm
Cable Shielding Non-shielded
Cable Type Power Cable
Conductor Material Copper, Aluminum
Conductor Sizes (Imperial) 2 AWG
Conductor Sizes (Metric) 35 mm²
Connector Included No
Connector Maximum Outside Diameter 0.687 in
Connector Maximum Outside Diameter (metric) 17.0 mm
Dielectric Strength (V/mil) 365 V/mil
Elongation 750 %
For connection of paper - with plasticinsulated cables No
Indoor/Outdoor Both
Insulation O.D. Range 0.20-0.75 in
Insulation O.D. Range (Metric) 5-19 mm
Insulation Outer Diameter (Imperial) 0.2 in, 0.21 in, 0.22 in, 0.23 in, 0.24 in, 0.25 in, 0.26 in, 0.27 in, 0.28 in, 0.29 in, 0.3 in, 0.31 in, 0.32 in, 0.33 in, 0.34 in, 0.35 in, 0.36 in, 0.37 in, 0.38 in, 0.39 in, 0.4 in, 0.41 in, 0.42 in, 0.43 in, 0.44 in, 0.45 in, 0.46 in, 0.47 in, 0.48 in, 0.49 in, 0.5 in, 0.51 in, 0.52 in, 0.53 in, 0.54 in, 0.55 in, 0.56 in, 0.57 in, 0.58 in, 0.59 in, 0.6 in, 0.61 in, 0.62 in, 0.63 in, 0.64 in, 0.65 in, 0.66 in, 0.67 in, 0.68 in, 0.69 in, 0.7 in, 0.71 in, 0.72 in, 0.73 in, 0.74 in, 0.75 in
Insulation Outer Diameter (metric) 5.08 mm, 5.334 mm, 5.588 mm, 5.842 mm, 6.096 mm, 6.35 mm, 6.604 mm, 6.858 mm, 7.112 mm, 7.366 mm, 7.62 mm, 7.874 mm, 8.128 mm, 8.382 mm, 8.636 mm, 8.89 mm, 9.144 mm, 9.398 mm, 9.652 mm, 9.906 mm, 10.16 mm, 10.414 mm, 10.668 mm, 10.922 mm, 11.176 mm, 11.43 mm, 11.684 mm, 11.938 mm, 12.192 mm, 12.446 mm, 12.7 mm, 12.954 mm, 13.208 mm, 13.462 mm, 13.716 mm, 13.97 mm, 14.224 mm, 14.478 mm, 14.732 mm, 14.986 mm, 15.24 mm, 15.494 mm, 15.748 mm, 16.002 mm, 16.256 mm, 16.51 mm, 16.764 mm, 17.018 mm, 17.272 mm, 17.526 mm, 17.78 mm, 18.034 mm, 18.288 mm, 18.542 mm, 18.796 mm, 19.05 mm
Maximum Conductor Size (Imperial) 2/0 AWG
Maximum Conductor Size (Metric) 70 mm²
20 of 32