1. Canada
  2. All 3M Products
  3. Electrical
  4. Wire & Cable
  5. Tubing & Molded Parts
  6. Cable Sleeves
  7. 3M™ Rejacketing Sleeve, RJS-4-4FT, three 4 ft (1.2 m) coils, 3.3-35 kV

3M™ Rejacketing Sleeve, RJS-4-4FT, three 4 ft (1.2 m) coils, 3.3-35 kV

  • 3M ID 7000134299
  • UPC 50051141039379

Installs quickly and accommodates a wide range of cable sizes

No torches, heat or special tools required

Seals tight and retains resiliency and pressure

View more details

Details

Highlights
  • Installs quickly and accommodates a wide range of cable sizes
  • No torches, heat or special tools required
  • Seals tight and retains resiliency and pressure
  • Excellent resistance to ozone and ultra-violet radiation
  • Easy to adjust sleeve length
  • Good solvent resistance
  • Pre-cut into three pieces
  • Designed to be used in conjunction with 3M™ Cold Shrink Breakout Boots and 3M™ Silicone Rubber Terminations

3M™ Rejacketing Sleeves RJS Series are designed so that 3M™ Cold Shrink QT-III and Q-TIII Silicone Rubber Terminations can be used on 3/C (three conductor) medium voltage shielded power cables of tape shield, wire shield, armoured and non-armoured configurations. Rejacketing sleeves are designed to protect the phase legs (core) of 3/C shielded power cable from exposure to moisture, corrosion, ozone, ultra-violet radiation, physical contact and other hazards that are associated with termination operating environments. Rejacketing sleeves are designed to be used in conjunction with 3M™ Cold Shrink Breakout Boots and Silicone Rubber Terminations. The 3M™ Rejacketing Sleeve RJS-4 has a metallic shield diameter range of 1.02-1.28 inch(25.9-32.4 mm), a voltage range of 3.3-35.0 kV, and three 4-foot (1.2 m) lengths per case.

3M™ Rejacketing Sleeves RJS Series are designed so that 3M™ Cold Shrink QT-III & Q-TIII Silicone Rubber Terminations can be used on 3/C (three conductor) medium voltage shielded power cables of tape shield, wire shield, armoured and non-armoured configurations. Rejacketing sleeves are designed to protect the phase legs (core) of 3/C shielded power cable from exposure to moisture, corrosion, ozone, ultra-violet radiation, physical contact and other hazards that are associated with termination operating environments. Rejacketing sleeves are designed to be used in conjunction with 3M™ Cold Shrink Breakout Boots and Silicone Rubber Terminations.

Suggested applications
  • Protect shielded phase legs (cores) of 3/C medium voltage (35 kV and less) power cables after the jacket has been removed in preparation for terminating
  • Are used to protect shielded phase legs (cores) of 3/C medium voltage (35 kV and less) power cables after the jacket has been removed in preparation for terminating

Typical Properties