1. Canada
  2. All 3M Products
  3. Electrical
  4. Power Cable Connectors
  5. Power Cable Terminations
  6. 3M™ Cold Shrink QT-III Three Conductor Indoor Termination Kit, 7625-T-110-3W, 15 kV, 1.18-1.52 in (30.0-38.6 mm) cable insulation O.D., 3 terminations per kit

3M™ Cold Shrink QT-III Three Conductor Indoor Termination Kit, 7625-T-110-3W, 15 kV, 1.18-1.52 in (30.0-38.6 mm) cable insulation O.D., 3 terminations per kit

  • 3M ID 7100028032
  • UPC 00054007047391

Quick installation with versatile one-piece design

No torches, heat or special tools required

Hi-K stress control

View more details
Frequently viewed resources
PDF (1) Copy 26Safety Data Sheet (PDF)

Details

Highlights
  • Quick installation with versatile one-piece design
  • No torches, heat or special tools required
  • Hi-K stress control
  • Excellent tracking resistance
  • Includes everything required to make 3 terminations (except lugs)
  • Also includes Rejacketing Sleeve Assembly and Breakout boot
  • Conductor size ranges: 5 kV: 800-1000 kcmil, 8 kV: 750-1000 kcmil, 15 kV: 500-750 kcmil

3M™ Cold Shrink QT-III, Three Conductor Termination Kit 7600-T-3W is tubular and designed for cables without internal ground wires for indoor installations. The Hi-K stress control design delivers excellent BIL performance and lower surface stress, resulting in a more compact termination.

Each kit contains: One 3M™ Cold Shrink Silicone Rubber Breakout Boot Assembly, three 3M™ Silicone Rubber Phase Re-Jacketing Sleeve Assemblies, three 3M™ Cold Shrink Silicone Rubber Termination Assemblies, one roll of 3M™ Tinned Copper Ground Braid, three small 3M™ Constant-Force Springs, one large 3M™ Constant-Force Spring, two strips of 3M™ Scotch® Mastic 2230, one roll of Scotch® Super 33+™ Vinyl Electrical Tape, one 3M™ Cable Preparation Kit CC-2, and one Instruction Sheet.

Suggested applications
  • Terminating solid dielectric shielded power cable
  • Tape shielded cable (armored or unarmored)
  • Free-hanging or bracket-mounting arrangements
  • Compact design provides for easier installation in restricted spaces
  • For cables without ground wires
  • *For Wire and Unishield® cables please contact your 3M representative for technical assistance

Typical Properties

BIL

110 kV

Brands

3M™

Breakout Boot

Yes

Cable Insulation Outside Diameter Range

1.18-1.52 in

Cable Insulation Outside Diameter Range (metric)

30.0-38.6 mm

Cable Shielding

Wire Shield, Tape Shield, UniShield®

Case Quantity

1

Conductor Sizes (Imperial)

500 kcmil, 600 kcmil, 700 kcmil, 750 kcmil, 800 kcmil, 900 kcmil, 1000 kcmil

Indoor/Outdoor

Indoor Non-skirted

Insulation Level

100%, 133%

Insulation Outer Diameter (Imperial)

1.18 in, 1.19 in, 1.2 in, 1.21 in, 1.22 in, 1.23 in, 1.24 in, 1.25 in, 1.26 in, 1.27 in, 1.28 in, 1.29 in, 1.3 in, 1.31 in, 1.32 in, 1.33 in, 1.34 in, 1.35 in, 1.36 in, 1.37 in, 1.38 in, 1.39 in, 1.4 in, 1.41 in, 1.42 in, 1.43 in, 1.44 in, 1.45 in, 1.46 in, 1.47 in, 1.48 in, 1.49 in, 1.5 in, 1.51 in, 1.52 in

Insulation Outer Diameter (metric)

29.972 mm, 30.226 mm, 30.48 mm, 30.734 mm, 30.988 mm, 31.242 mm, 31.496 mm, 31.75 mm, 32.004 mm, 32.258 mm, 32.512 mm, 32.766 mm, 33.02 mm, 33.274 mm, 33.528 mm, 33.782 mm, 34.036 mm, 34.29 mm, 34.544 mm, 34.798 mm, 35.052 mm, 35.306 mm, 35.56 mm, 35.814 mm, 36.068 mm, 36.322 mm, 36.576 mm, 36.83 mm, 37.084 mm, 37.338 mm, 37.592 mm, 37.846 mm, 38.1 mm, 38.354 mm, 38.608 mm

Insulation Rejacketing

Yes

Lug/Stem Connector Included in Kit

No

Maximum Installed Length

12.00 in

Number of Conductors

3

Product Series

7600-T-3W

Voltage

5 kV, 8 kV, 15 kV

Voltage Application

Medium Voltage

Resources