1. Canada
  2. All 3M Products
  3. Building Materials
  4. Fire Protection
  5. Firestop Sealants, Foams, Putties & Mortars
  6. 3M™ Fire Barrier Sealant, IC 15WB+, 20 fl. oz. (591.47 mL)

3M™ Fire Barrier Sealant, IC 15WB+, 20 fl. oz. (591.47 mL)

  • 3M ID 7000059405
  • UPC 00051115165603
Container Size (Metric) 591 mL
Container Size (Imperial) 20 fl oz
Product Type Sealant

Firestop tested up to 3 hours in accordance with ASTM E 814 (UL 1479) and CAN/ULC S115

Fire Resistance tested for static construction joint systems in accordance with ASTM E 1966 (UL 2079)

Helps minimize sound transfer

View more details
Frequently viewed resources
PDF (1) Copy 26Safety Data Sheet (PDF)

Details

Highlights
  • Firestop tested up to 3 hours in accordance with ASTM E 814 (UL 1479) and CAN/ULC S115
  • Fire Resistance tested for static construction joint systems in accordance with ASTM E 1966 (UL 2079)
  • Helps minimize sound transfer
  • Compatible for use with CPVC piping
  • Applied with conventional caulking equipment (excellent caulk rate)
  • Expansive UL-listed and other third-party systems
  • Halogen-free
  • Sag-resistant
  • Excellent adhesion
  • Re-enterable/repairable
  • Paintable
  • Easy clean up with water
  • Dries to yellow colour, no mixing required

3M™ Fire Barrier Sealant 15WB+ is a high-performance latex-based intumescent firestop sealant. When properly installed, this product provides up to three hours of fire protection in tested and listed systems.

When properly installed, the 3M™ Fire Barrier Sealant helps prevent the spread of fire, smoke and noxious gas. In addition, this product acts as an acoustic barrier by minimizing noise transfer (STC-Rating of 54 when tested in a STC 54-rated wall assembly), helps create a smoke seal for systems requiring the optional L-Rating, meets the intent of LEED® green building program credits VOC environmental regulations, meets International Building Code (IBC) and other key life safety building code requirements.

Suggested applications
  • Ideal for sealing single or multiple through penetrations in fire-rated constructions
  • Typically used in mechanical, electrical and plumbing applications to firestop openings created by penetrations in fire-rated floors, floor/ceilings or walls such as metallic pipe, plastic pipe (excluding CPVC), conduit, power and communication cable, cable trays, bus ways, combos, insulated pipe and HVAC duct penetrations
  • Use to firestop blank openings and static construction joints

Typical Properties

Resources