1. Canada
  2. All 3M Products
  3. Building Materials
  4. Fire Protection
  5. Firestop Sealants, Foams, Putties & Mortars
  6. 3M™ Fire Barrier Sealant, FD 150+, blue, 28 fl. oz. (828 mL)

3M™ Fire Barrier Sealant, FD 150+, blue, 28 fl. oz. (828 mL)

3M ID 7000133848
  • Firestop tested up to 3 hours in accordance with ASTM E 814 (UL 1479) and CAN/ULC S115
  • Fire Resistive Joint System tested up to 4 hours in accordance with ASTM E 1966 (UL 2079)
  • ±19% movement capability
  • Helps minimize noise transfer
 More...
View all details
Specifications
Brand
3M™
Colour Family
Blue
Fire Rating
4 Hour
Hardness
60 Shore A
Movement Capability
19%, 19%
NPVI Mktg
Yes
Product Key
FD 150+
Product Type
Sealant
Smoke Seal
Yes
Sound Barrier
56 in 56
Volume (Imperial)
28 fl oz
Volume (metric)
828 mL
Water-tight
No
Details
  • Firestop tested up to 3 hours in accordance with ASTM E 814 (UL 1479) and CAN/ULC S115
  • Fire Resistive Joint System tested up to 4 hours in accordance with ASTM E 1966 (UL 2079)
  • ±19% movement capability
  • Helps minimize noise transfer
  • Applied with conventional caulking equipment (excellent caulk rate)
  • Halogen-free
  • Sag-resistant
  • Excellent adhesion
  • Paintable
  • Re-enterable/repairable
  • Available in blue, red or limestone, no mixing required

3M™ Fire Barrier Sealant FD150+ is a ready-to-use, gun-grade, latex-based elastomeric sealant that cures upon exposure to the atmosphere to form a monolithic flexible firestop seal.

When properly installed, this product provides up to 4 hours of fire protection in tested and listed systems and helps prevent the spread of fire, smoke and noxious gas. It remains elastomeric (compression/extension capability of ± 19%) and exhibits excellent adhesion to a full range of construction substrates. In addition, this product acts as an acoustic barrier by minimizing noise transfer (STC-Rating of 56 when tested in a STC 56-rated wall assembly), helps create a smoke seal for systems requiring the optional L-Rating, meets the intent of LEED® green building program credits VOC environmental regulations,, meets International Building Code (IBC) and other key life safety building code requirements.

Suggested Applications

  • Firestops construction joints including: bottom-of-wall, head-of-wall and wall-to-wall
  • Typically used in mechanical, electrical and plumbing applications to firestop openings created by penetrations in fire-rated floors, floor/ceilings or walls such as metallic pipe, plastic pipe (excluding CPVC), conduit, power and communication cable, cable trays, bus ways, combos, insulated pipe and HVAC duct penetrations